Data storage
All lab data lives on the lab drive (LRZ cloud storage), not on laptops or USB sticks. This page explains how the drive is organized and the rules for working with it.
Top-level folders
Section titled “Top-level folders”| Folder | Content |
|---|---|
| Home Folders | One folder per lab member: your data, analysis, results and meeting slides (see below). |
| Projects | Shared project work that belongs to the lab rather than to one person, for example the CRISPR arrayed screening protocol. |
| Protocols | Bench protocols, with older versions kept for reference. The current versions are on this website. |
| Materials | Plasmid, antibody and primer lists, lab inventory, cell storage, labels, sequences. |
| Abstracts and Poster | Abstracts, posters and the figures for them, one folder per event (YYYY-MM Event). |
| Einkauf und Bestellungen | Ordering, quotes, invoices, accounts and equipment lists. |
| S2 GenTSV | Genetic engineering (S2) documentation and reports. |
| Shipping & import of research material | Import permits, declarations and one folder per incoming or outgoing shipment. |
| Templates & corporate design | Lab logos and presentation templates. |
Your home folder
Section titled “Your home folder”Every member has a folder in Home Folders with the same numbered structure, so anyone can find their way around someone else’s folder:
| Folder | Content |
|---|---|
| 01_Data | Raw data, one subfolder per project or experiment. |
| 02_Analysis | Scripts, notebooks and processed data. |
| 03_Results | Figures, tables and summaries that come out of the analysis. |
| 04_Lab meeting | Your lab meeting presentations. |
| 05_1-1 meeting | Material for one-to-one meetings. |
Keep the information flowing in one direction: Data → Analysis → Results. Analysis reads from 01_Data and writes to 02_Analysis and 03_Results; it never writes back into 01_Data.
- Never edit raw data. Instrument output, sequencing files and exported plate-reader or FACS files stay exactly as they came off the machine. Work on a copy in
02_Analysis. - Use the same project name in all three folders. If the data is in
01_Data/Project01_CRISPRi_Screen, the analysis and results go into folders with the same project name, so a result can always be traced back to its data. - Date your experiments. Start experiment folders with
YYMMDD, for example260302_ValidationLibrary_Virus. Folders then sort chronologically. - Put a short README in every project folder. Three lines are enough: what the experiment was, who did it, and the matching eLabFTW entry.
- Keep scripts and data apart. Code goes into
02_Analysis(ideally under version control), never between the raw files. - No duplicates of shared files. Lists such as plasmids, antibodies and primers exist once, in Materials. Link to them; do not copy them into your folder.
- Do not use temporary or final-looking names. Avoid
final,final2ornew. Use the date, or a version number as inv2-1.
Large files
Section titled “Large files”Imaging, sequencing and other large datasets belong in 01_Data as well. Do not copy them around. Reference the location in the README instead.
Leaving the lab
Section titled “Leaving the lab”Before you leave, tidy your home folder, add READMEs to the projects that others will continue and tell Johannes. Your folder stays on the drive.